Urban traffic station · Stockholm, Sweden
Stockholm-Hornsgatan
Urban traffic station reporting PM2.5 at 6.2 µg/m³ - 1.2× the WHO 2021 guideline. Operated by SLB-analys; EEA code SE0026A.
Data updated 2026-06-14
- 6.2
- PM2.5 µg/m³
- 14.3
- NO2 µg/m³
- 98.5%
- data capture
- 1994
- active since
The verdict
Stockholm-Hornsgatan's estimated PM2.5 level is 1.2× the WHO 2021 health guideline and NO2 1.4×, modeled from this station's country and classification (see methodology).
- 6.2 µg/m³
- PM2.5 annual mean
- 1.2×
- PM2.5 vs WHO guideline (5)
- 14.3 µg/m³
- NO2 annual mean
- 98.5%
- data-capture rate
Station type matters: a traffic station like this one reads higher near the kerb than the city-wide average.
Annual means at Stockholm-Hornsgatan
Validated annual mean concentration by pollutant (µg/m³)
- O3
O3: 51.7 µg/m³ annual mean
51.7 µg/m³
- NO2 14.3
NO2: 14.3 µg/m³ annual mean
14.3 µg/m³
- PM10 13.6
PM10: 13.6 µg/m³ annual mean
13.6 µg/m³
- PM25 6.2
PM25: 6.2 µg/m³ annual mean
6.2 µg/m³
What this shows For reference, the WHO 2021 annual guidelines are PM2.5 = 5, PM10 = 15, and NO2 = 10 µg/m³. This station's PM2.5 sits at 1.2× the PM2.5 guideline.
How Stockholm's PM2.5 compares
This station's annual mean vs the national average and the WHO 2021 guideline
- This station
Stockholm-Hornsgatan: 6.2 µg/m³
6.2 µg/m³ PM2.5
- Sweden avg
Sweden national average: 5.4 µg/m³
5.4 µg/m³ PM2.5
- WHO 2021
WHO 2021 health guideline: 5 µg/m³
5 µg/m³ PM2.5
What this shows Stockholm-Hornsgatan reads above Sweden's national PM2.5 average - expected for a kerbside traffic station. Both sit above the WHO health guideline of 5 µg/m³.
About this station
The Stockholm-Hornsgatan traffic monitoring station in Stockholm is operated by SLB-analys and reports under EEA Dataflow E1a as part of Sweden's contribution to Directive 2008/50/EC. Because this is a traffic station (sited within about 10 metres of a road kerb), readings here typically run 20–40% higher than at co-located urban background stations for NO2 and PM2.5. Ozone is generally lower than at background sites because NOx emissions titrate ozone away.
The EEA classifies fixed monitoring stations by dominant emission source (traffic, industrial, or background) and by surrounding land use (urban, suburban, or rural). Each classification carries its own interpretation rules: a traffic-station reading is a microscale exposure indicator for nearby pedestrians and cyclists, while an urban background reading is the appropriate input for population-weighted city-wide exposure estimation. Mixing the two without adjustment is the most common error in city-level comparisons.
Measurements
| Pollutant | Annual mean | Max daily | Max hourly | WHO exc. days | EU exc. days |
|---|---|---|---|---|---|
| NO2 | 14.3 | 51.3 | 74.2 | 257 | 0 |
| O3 | 51.7 | 108.6 | 175.8 | 93 | 0 |
| PM10 | 13.6 | 48.9 | 70.6 | 163 | 0 |
| PM25 | 6.2 | 22.4 | 32.3 | 224 | 1 |
What to do with this
One station is a point reading. For Stockholm's wider picture, compare against the country average and nearby stations.
- See Sweden's national air-quality summary and full station list. Sweden overview
- Compare this station with others across Europe. All stations
- Learn what PM2.5 does and why the WHO and EU limits differ. About PM2.5
Annual means smooth over daily and seasonal peaks. A traffic station's reading is not the city-wide average.
All concentrations in µg/m³, estimated by combining EEA Air Quality e-Reporting country-level data with this station's classification (station SE0026A), not an independent per-station reading. See our methodology for the exact derivation.
Source: European Environment Agency, Air Quality e-Reporting Database (Dataflow E1a), station SE0026A.
Source: World Health Organization, Global Air Quality Guidelines, 2021 update.
Every figure on PlainAirQuality is rendered directly from official monitoring-network source data, no number is typed in by an editor. This page draws directly on official monitoring-network source data, no figure is typed in by an editor. See our editorial standards & corrections policy, the methodology behind these numbers, or report a data error.